SE FOXBORO Model CFS600A

Online PDF

FOXBORO Coriolis twin V-tube design mass flowmeter consists of two measuring tubes

Designed to meet the requirements of general purpose liquid and gas applications, the extended low temperature range of -200°C / -328°F also makes the CFS600A suitable for Liquid Natural Gas (LNG) and cryogenic applications.

  • Innovative twin V-tube design
  • Optional insulation / heating jacket
  • Optimised flow divider for minimum pressure loss
  • Modular electronics concept: electronics and sensor are easy to replace
  • Self draining when mounted vertically
  • Stability with entrained gas, even with gas concentrations 0…100%
  • Custody transfer approved for liquids and gases

Industries

  • Oil and Gas
  • Water and waste water
  • Pharmaceutical
  • Chemical
  • F&B

Applications

  • Crystallising, solidifying and cryogenic products
  • Tanker loading
  • General purpose applications
  • CIP and SIP >130°C
  • Liquid Natural Gas (LNG)
  • Supercritical gases

Overview

  • Twin tube flowmeter
  • Available in Duplex, Hastelloy and Stainless Steel
  • 9 sizes: DN8, 10, 15, 25, 50, 80, 100, 150, 200
  • Max pressure 200 bar (2900 psi)
  • Temperature Range : 0-200° to +400 °C
  • Max flow rate 550,000 kg/h
  • Accuracy +/- 0.10% of MV + zero instability
  • PED approved
  • Hazardous area, cryogenic and hygienic approvals